Acta Med Philipp. 2024 Aug 30;58(15):32-38. doi: 10.47895/amp.vi0.7618. eCollection 2024.
ABSTRACT
OBJECTIVES: To validate a method in detecting SARS-CoV-2 via RT-qPCR in pregnant and non-pregnant samples other than nasopharyngeal swabs and/or oropharyngeal swabs such as cervical, rectal, amniotic fluid, placental, umbilical cord blood, and breastmilk.
METHODS: We performed a validation experiment using MGI easy extraction kits and BGI PCR kits on non-conventional specimens, including cervical, rectal, amniotic fluid, placental, umbilical cord blood, and breastmilk to detect and confirm the presence of SARS-CoV-2. In addition, we tested the validated method on 572 purposively sampled field-collected non-conventional specimens from a cohort of 109 unvaccinated pregnant and 47 unvaccinated non-pregnant women to assess which candidate non-conventional maternal- and fetal-associated specimens may contribute to maternal-fetal viral vertical transmission.
RESULTS: Positive detection of SARS-CoV-2 viral RNA in non-conventional specimens was demonstrated and verified. Of the 572 non-conventional samples tested, 1.8% (10/572) were positively validated by RT-qPCR for SARS-CoV-2 in the maternal-associated specimens particularly the rectal (5), placental (1), and cervical (4) swabs among six pregnant and four non-pregnant individuals. In contrast, no SARS-CoV-2 viral RNA was detected in fetal-associated specimens.
CONCLUSION: The results of the validation study may serve as an additional diagnostic screening layer to support maternal-child care. Furthermore, viral detection in these non-conventional maternal specimens may also be utilized to provide guidance in the clinical management of neonates, and pregnant women during delivery.
PMID:39308885 | PMC:PMC11413462 | DOI:10.47895/amp.vi0.7618