J Perinatol. 2025 Nov 19. doi: 10.1038/s41372-025-02461-4. Online ahead of print.
ABSTRACT
Accurate confirmation of endotracheal tube (ETT) placement is critical in neonatal resuscitation. This systematic review and meta-analysis assessed the diagnostic accuracy of point-of-care ultrasound (POCUS) for confirming ETT placement in neonates. We searched PubMed, Scopus, Web of Science, and Cochrane Library through May 2025. Eligible studies included neonates (<28 days) and compared POCUS with gold-standard confirmation (capnography, chest radiography, or direct laryngoscopy). Diagnostic performance was pooled using a bivariate random-effects model. Thirteen studies (930 neonates) met inclusion criteria. POCUS showed pooled sensitivity of 93% and specificity of 59%, with an area under the SROC curve of 92%. tracheal placement was confirmed in 99%, and esophageal misplacement detected in 4%. Subgroup analysis indicated higher accuracy by neonatologists and with linear transducers. POCUS offers a rapid, radiation-free method for confirming neonatal ETT placement. Broader implementation requires standardized techniques and operator training.
PMID:41261147 | DOI:10.1038/s41372-025-02461-4